Leica FlexLine TS06 Plus delivers measurements that are extremely precise from a selection of Electronic Distance Measurements (EDM) options. Specifically designed for applications of medium accuracy it comes with the easy setup with a laser plummet and guided process at start-up. The ergonomic key layout and large display provides error-free data input and makes operation simple.
Features of the Leica FlexLine TS06 Plus include a built-in easy to use an alphanumerical keyboard for fast entry of numbers, special characters, and numbers. This not only increases speed and productivity but also minimizes errors.
The Flexline TS06 Communication Side Cover allows for connections to any data collector via a cable-free Bluetooth connection. It is ideally used with Leica Viva CS10 or Leica CS15 using SmartWorks software. The USB functionality gives transfer flexibility of data files including GSI, ASCII, DXF, CSV, and more. The Flexline TS06 also has a large internal memory and can store up to 100000 fix points and 60000 measurements.
This Total Station uses Lithium-Ion batteries for long life, fast charging, and an operation time of 30 hrs. The Flexline weighs 5.1kg including the GEB211 battery and tribrach. Its the container is light, tough, and keeps the instrument with all the accessories dust and waterproof.
Leica FlexLine TS06 Plus Specification
Angle Measurement (Hz, V) |
|
Accuracy (Standard deviation ISO-17123-3) |
5” (1.5 mgon) |
Method | Absolute, continuous, diametrical |
Display resolution | 0.1” / 0.1 mgon / 0.01 mil |
Compensation | Quadruple axis compensation (Setting On, Off) |
Compensator Setting accuracy | 0.5”, 1”, 1.5” |
Distance Measurement with Reflector |
|
Range Round prism GPR1 | 3’500 m |
Range Reflective tape (60 mm x 60 mm) |
250 m |
Accuracy / Measurement time (Standard deviation ISO-17123-4) |
Standard: 1.5 mm+2 ppm / typ. 2.4 s, Fast: 3 mm+2 ppm / typ. 0.8 s, Tracking: 3 mm+2 ppm / typ. <0.15 s |
Distance Measurement without Reflector |
|
Range (90% reflective) FlexPointPinPoint – Power PinPoint – Ultra |
30 m > 400 m (optional) > 1000 m (optional) |
Accuracy / Measurement time (Standard deviation ISO-17123-4) |
2 mm+2 ppm2 / typ. 3 s |
Laser dot size | At 30 m: approx. 7 mm x 10 mm, At 50 m: approx. 8 mm x 20 mm |
Data storage / Communication |
|
Extended Internal memory | Max.: 100’000 fixpoints, Max.: 60’000 measurements |
USB memory stick | 1 Gigabyte, Transfer time 1’000 points/second (optional) |
Interfaces | Serial (Baudrate 1’200 to 115’200) USB Type A and mini B, Bluetooth® Wireless (optional) |
Data formats | GSI / DXF / LandXML / CSV / user definable ASCII formats |
Electronic Guide Light |
|
Working Range (average atmospheric conditions) Positioning accuracy |
5 m – 150 m (optional)
5 cm at 100 m (optional) |
General | |
Telescope | |
Magnification | 30 x |
Resolving power | 3” |
Field of view | 1° 30’ (1.66 gon) / 2.7 m at 100 m |
Focusing range | 1.7 m to infinity |
Reticle | Illuminated, 5 brightness levels |
Keyboard and Display |
|
Display | Graphics, 160 x 280 pixels, illuminated, 5 brightness levels |
Keyboard | Alpha-numerical keyboard Second keyboard (optional) |
Operating System |
|
Windows CE | 5.0 Core |
Laserplummet | |
Type | Laser point, illuminated, 5 brightness levels |
Centering accuracy | 1.5 mm at 1.5 m Instrument height |
Battery | |
Type | Lithium-Ion |
Operating time | approx. 20 hours |
Weight | |
Total station including GEB211 and tribrach |
5.1 kg |
Environmental | |
Temperature range (operation) | -20° C to +50° C (-4° F to +122° F)Arctic Version -35° C to 50° C (-31° F to +122° F) (optional) |
Dust & splash proof (IEC 60529) |
IP55 |
Humidity | 95%, non condensing |