Leica Flexline TS02 Plus Total Station
The Leica Flexline TS02 Plus uses the Lithium-Ion batteries which give long life, fast charging and operation times of 20hours. The Flexline is protected to IP55 specification and is water and dust protected.
The Leica Flexline TS02 is easy to setup using a laser plummet with a guided process and start-up sequence. The ergonomic key layout and large display provides error-free data input and makes operation simple.
Leica FlexLine TS02 Plus – Ideal Today, Perfect Tomorrow
The ideal Total Station for standard measurement tasks. Designed especially for mid-to-low accuracy applications. It comes complete with a standard set of application software that guide you through your daily work.
Electronic Distance Measurement (EDM)
Prism: 3500m, 1mm accuracy
Non-Prism: 500m
FlexField & FlexOffice Software
FlexField on-board software and FlexOffice Software offer a broad range of functionality to cover all tasks. Benefit from simplicity and functionality in one solution.
Technical Specifications Leica TS02 Plus
Included Application Programs: Survey; Stake Out; Station Setup including: Resection, Local Resection, Helmert Resection, Orientation (Angles & Coordinates), Height Transfer, Area (Plan & Surface), DTM Volume calculation, Tie Distance (MLM), Remote Height, Hidden Point, Backsight Check, Offset, Reference Line
Theft protection mySecurity, PIN/PUK Code
Angle Measurement (Hz, V) | |
Accuracy 1) | 5″ (1.5 mgon) |
Method | Absolute, continuous, diametrical: at all models |
Display resolution | 0.1 / 0.1 mgon / 0.01 mil |
Compensation | Quadruple Axis compensation |
Compensator Setting Accuracy | 1.5″ |
Compensator range | 0.07 gon |
Endless Drives | Smooth movements with no delayed response time |
Distance Measurement with Reflector | |
Range 2) Round prism (Leica GPR1) | 3500 m |
Range 2) Reflective tape (60 mm x 60 mm) | 250 m > 500 m 8) |
Accuracy 3) | Precise+: 1.5 mm + 2.0 ppm |
Precise Fast: 2.0 mm + 2.0 ppm Tracking: 3.0 mm + 2.0 ppm |
|
Typical Measurement time 4) | 2.0 s |
Measurement time while in “Precise+” mode | 2.4 s |
Distance Measurement without Reflector 7) | |
Range 5) PinPoint R500 | 500 m |
Accuracy 3) | 2 mm + 2 ppm |
Laser dot size | At 30 m: approx. 7 x 10 mm |
At 50 m: approx. 8 x 20 mm | |
Data storage / Communication | |
Internal memory | Max.: 24’000 fixpoints, |
Max.: 13’500 measurements | |
Interfaces | Serial (Baudrate up to 115’200) |
Data formats | GSI / DXF / LandXML / CSV / user definable ASCII formats |
Telescope | |
Magnification / Resolving power | 30x / 3” |
Field of View | 1° 30’ (1.66 gon) |
2.7 m at 100 m | |
Focusing range | 1.7 m to infinity |
Reticle | Illuminated, 10 brightness levels |
Keyboard and Display | |
Keyboard and Display | Full Alpha-numerical keyboard with high resolution Black & White display, Graphics, 160 x 288 pixels, display illuminated, 5 brightness levels |
Position | Face I |
Operating System | |
Windows CE | 5.0 Core |
Laserplummet | |
Type | Laser point, 5 brightness levels |
Centering accuracy | 1.5 mm at 1.5 m |
Battery | |
Type | Lithium-Ion |
Operating time 6) | approx. 30 hours |
Battery charging time | 2.3 hours |
Weight | |
TS including GEB211 and tribrach | 5.1 kg |
Environmental | |
Temperature range (operation) | –20° C to +50° C |
(–4° F to +122° F) | |
Arctic Version –35° C to 50° C (–31° F to +122° F) | |
Dust / Water (IEC 60529) Humidity | IP55, 95%, non condensing |